Product Description
  • Provides Quantitative Exposure to Tobacco Products (Saliva or Urine Sample)
  • Easy to Use and Interpret Results with Provided Test Reference Ranges
  • Saturate the Padded Test End with Specimen, and Read Results in 15-30 Minutes
  • Ideal for Individuals, Research Studies, and Insurance Applications
  • Expires: 4/30/2020

TobacAlert Screening Info

According to the CDC, cigarette smoke kills more than 480,000 Americans each year and a staggering 41,000 of these deaths are due to exposure to second hand smoke.

TobacAlert is a home test that provides quick, accurate, and on-the-spot determination of a person’s level of exposure to tobacco products including second hand smoke.

TobacAlert™ can be used for:

  • For smokers and family members to get a more accurate measure of their smoking
  • Teachers and coaches who need to test their student athletes for tobacco use
  • For concerned parents who want to monitor their teenagers for potential tobacco use
TobacAlert nicotine test kits are intended for the semi-quantitative determination of cotinine in saliva and urine for the purpose of determining if an individual has been exposed to tobacco products such as cigarettes (including e-cigarettes), pipes or chewing tobacco within the past 48 hours.

The cutoff concentration for TobacAlert is 1000 ng/mL. Second hand smoke exposure (environmental tobacco smoke) may cause a positive result in a non-user of tobacco products. The TobacAlert Positive and Negative Controls are intended for in vitro diagnostic use for the quality control of the NicAlert® test.

TobacAlert Test Instructions:

Urine PDF Instructions


Saliva PDF Instructions


Warnings: Do not put any part of the TobacAlert strip in your mouth. Use the TobacAlert strip within 10 minutes of opening the pouch and use test samples (urine or saliva) at room temperature. Do not consume/handle food/drink when performing testing. Treat test samples as potential bio-hazards and discard after use. If the test samples are contaminated or the urine is cloudy or pink do not use the TobacAlert test strip.

TobacAlert Urine Test Instructions

Materials Needed: TobacAlert strip in its pouch with a valid expiration date, a clean disposable container for the urine sample, a timer, and a clean non absorbent surface.

1: Holding strip by the handle, dip the sample end (the exposed soft cotton end of the strip) into the urine sample to a depth of 1/2 inch (1 cm) holding the strip with forceps, tweezers or gloves if preferred. Do not immerse the strip lower than the maximum sample line on the strip.
2: Hold the strip in the urine for twenty seconds. Do not over-saturate.
3: Remove the strip and lay it flat on a nonabsorbent surface to develop for approximately 10 to 15 minutes until the blue indicator band substantially fades or disappears. During this period, you should see at least one reddish band appear in the numbered white zones in the strip.


TobacAlert Saliva Test Instructions

Materials Needed: TobacAlert strip in its pouch with a valid expiration date, a funnel, cap and collection vial, a timer, and a clean non absorbent surface.

1: Open the TobacAlert packet and lay the strip on the plastic laminated instruction card in the area marked on it for this purpose (do not put on paper or a Kleenex).
2: Open the Saliva Collection Kit and remove the funnel, the saliva tube container, and the snap-on top for the saliva container.
3: Place the funnel in the saliva tube container and spit/deposit saliva into the funnel, enough to fill at least half of the saliva tube container. Then discard the funnel.
4: Snap on the top of the saliva tube container. Squeeze 8 drops from the inverted saliva tube directly onto the white padded end of the TobacAlert strip.


How to Read TobacAlert Test Results:

1: A reddish color must appear in at least one of the numbered zones (Levels 0 – 6) on the strip and there must not be any noticeable color in the area between the sample end (the exposed soft cotton end of the strip) and Level 0. Otherwise the results are not valid and the test must be repeated with a new TobacAlert strip. If the color appears as an indistinct smear throughout the strip, the results are not valid and the test must be repeated with a new TobacAlert strip.
2: Find the lowest numbered zone (Level 0 – 6) on the strip with a reddish color in it. This lowest level is the TobacAlert test result. Note: The strip may have more than one level in which there is a reddish band or color. Different levels may have different shades or colors in them. The presence of a reddish color in the lowest numbered level is the test result
3: The TobacAlert test result is the lowest numbered level on the strip with a reddish band or color in it. If there is doubt as to the lowest level, express the result as a range of 2 levels, eg. “1-2” or “5-6,” etc., or repeat the test.
Levels Interpretation
  • Level 3 or higher (Level 4, 5, or 6) indicates use of tobacco products
  • Level 0 indicates no detectable level of cotinine or tobacco product use
  • Levels 1 (10-30 ng/mL) and Level 2 (30-100 ng/mL) indicate no use of tobacco products
  • A borderline result at the cutoff (i.e. TobacAlert level “2-3”) could be a smoker or a non-smoker. Repeat testing with another urine sample is recommended.
Ordering More Than 75 Tests?
Apply For Custom Pricing!
CASE QTY:

Why Customers Choose Us?

Free Shipping on orders over $75

Free Shipping on orders $75+

$7 Shipping below $75

Same day shipping for orders before 4pm EST

Same-Day Shipping

for Orders by 4pm EST

Average Shelf Life of 12 to 18 months

Average Shelf Life

of Products is 12-18 Months

5% of all profits go back into our community

5% of All Profits

Go Back Into Our Community

TobacAlert Screening Info

According to the CDC, cigarette smoke kills more than 480,000 Americans each year and a staggering 41,000 of these deaths are due to exposure to second hand smoke.

TobacAlert is a home test that provides quick, accurate, and on-the-spot determination of a person’s level of exposure to tobacco products including second hand smoke.

TobacAlert™ can be used for:

  • For smokers and family members to get a more accurate measure of their smoking
  • Teachers and coaches who need to test their student athletes for tobacco use
  • For concerned parents who want to monitor their teenagers for potential tobacco use
TobacAlert nicotine test kits are intended for the semi-quantitative determination of cotinine in saliva and urine for the purpose of determining if an individual has been exposed to tobacco products such as cigarettes (including e-cigarettes), pipes or chewing tobacco within the past 48 hours.

The cutoff concentration for TobacAlert is 1000 ng/mL. Second hand smoke exposure (environmental tobacco smoke) may cause a positive result in a non-user of tobacco products. The TobacAlert Positive and Negative Controls are intended for in vitro diagnostic use for the quality control of the NicAlert® test.

TobacAlert Test Instructions:

Urine PDF Instructions


Saliva PDF Instructions


Warnings: Do not put any part of the TobacAlert strip in your mouth. Use the TobacAlert strip within 10 minutes of opening the pouch and use test samples (urine or saliva) at room temperature. Do not consume/handle food/drink when performing testing. Treat test samples as potential bio-hazards and discard after use. If the test samples are contaminated or the urine is cloudy or pink do not use the TobacAlert test strip.

TobacAlert Urine Test Instructions

Materials Needed: TobacAlert strip in its pouch with a valid expiration date, a clean disposable container for the urine sample, a timer, and a clean non absorbent surface.

1: Holding strip by the handle, dip the sample end (the exposed soft cotton end of the strip) into the urine sample to a depth of 1/2 inch (1 cm) holding the strip with forceps, tweezers or gloves if preferred. Do not immerse the strip lower than the maximum sample line on the strip.
2: Hold the strip in the urine for twenty seconds. Do not over-saturate.
3: Remove the strip and lay it flat on a nonabsorbent surface to develop for approximately 10 to 15 minutes until the blue indicator band substantially fades or disappears. During this period, you should see at least one reddish band appear in the numbered white zones in the strip.


TobacAlert Saliva Test Instructions

Materials Needed: TobacAlert strip in its pouch with a valid expiration date, a funnel, cap and collection vial, a timer, and a clean non absorbent surface.

1: Open the TobacAlert packet and lay the strip on the plastic laminated instruction card in the area marked on it for this purpose (do not put on paper or a Kleenex).
2: Open the Saliva Collection Kit and remove the funnel, the saliva tube container, and the snap-on top for the saliva container.
3: Place the funnel in the saliva tube container and spit/deposit saliva into the funnel, enough to fill at least half of the saliva tube container. Then discard the funnel.
4: Snap on the top of the saliva tube container. Squeeze 8 drops from the inverted saliva tube directly onto the white padded end of the TobacAlert strip.


How to Read TobacAlert Test Results:

1: A reddish color must appear in at least one of the numbered zones (Levels 0 – 6) on the strip and there must not be any noticeable color in the area between the sample end (the exposed soft cotton end of the strip) and Level 0. Otherwise the results are not valid and the test must be repeated with a new TobacAlert strip. If the color appears as an indistinct smear throughout the strip, the results are not valid and the test must be repeated with a new TobacAlert strip.
2: Find the lowest numbered zone (Level 0 – 6) on the strip with a reddish color in it. This lowest level is the TobacAlert test result. Note: The strip may have more than one level in which there is a reddish band or color. Different levels may have different shades or colors in them. The presence of a reddish color in the lowest numbered level is the test result
3: The TobacAlert test result is the lowest numbered level on the strip with a reddish band or color in it. If there is doubt as to the lowest level, express the result as a range of 2 levels, eg. “1-2” or “5-6,” etc., or repeat the test.
Levels Interpretation
  • Level 3 or higher (Level 4, 5, or 6) indicates use of tobacco products
  • Level 0 indicates no detectable level of cotinine or tobacco product use
  • Levels 1 (10-30 ng/mL) and Level 2 (30-100 ng/mL) indicate no use of tobacco products
  • A borderline result at the cutoff (i.e. TobacAlert level “2-3”) could be a smoker or a non-smoker. Repeat testing with another urine sample is recommended.