5 Panel DrugConfirm™ Flat Urine Drug Test Cup + ADU | https://testcountry.com/products/5-panel-drugconfirm-advanced-flat-panel-urine-drug-test-cup-with-adulterants

5 Panel DrugConfirm™ Flat Urine Drug Test Cup + ADU

Product Description
  • Configurations Available:
    254 | AMP/COC/mAMP/OPI/THC + OX/SG/pH
  • Flat Sided Results Panel for Photocopying Results to Keep Records
  • Best Value for an Affordable and High Quality Cup
  • Exclusive Temperature Strip and Adulterants for Specimen Validity
  • Provides Hospital Quality, 99% Accurate Results in Minutes
  • CLIA Waived, FDA 510(k) Approved, and CE Marked

DrugConfirm Urine Drug Screening

Our DrugConfirm Advanced 5 Panel Flat Sided Instant Drug Test Cup is a fully-integrated test cup that detects 5 different drugs of abuse and also includes adulterant testing and a temperature strip to help prevent specimen tampering by the donor.

This test cup detects the following drugs in a simple urine sample:

  • Amphetamines (AMP)
  • Cocaine (COC)
  • Marijuana (THC)
  • Methamphetamines (mAMP)
  • Opiates (OPI)

Plus the following adulterants:

  • Oxidants (OX)
  • Specific Gravity (SG)
  • pH Levels
The flat panel results window makes for ease of photocopying results for your drug testing program records. Once the testing is completed and the cup is sealed, the test is biohazardous safe so you can simply throw the cup and sample away when you are done.

Our DrugConfirm Advanced test cup provides hospital quality results within 5 minutes with up to 99% results accuracy. Staffing agencies, human resource departments, law enforcement agencies and more all love this cup!

If I suspect recent drug use, when should I collect a urine specimen for this test?

The minimum detection time for most drugs is approximately 2 to 7 hours, so you may collect a urine sample after this time frame.

What is a drug test cut-off level?

The drug test cut-off level is the specified amount of a specific drug metabolite in a urine sample. Above this level, the test is considered positive. Below this level, a test is considered negative.

5 Panel Drug Test Cup Instructions for Use:


1: Remove test cup from the foil pouch and label the device with the donor's information.
2: Remove the test cup lid and instruct the donor to urinate directly into the cup, making sure to provide a sample that's between the minimum line of 30ml and the maximum line of 110ml.
3: Once the donor has collected their urine sample, ask them to securely place the lid back on the test device, then return the test to the collection official.
4: Peel back the label to reveal the test panels and verify the adulteration strip against the color chart provided. If results indicate that adulteration has occurred, discard the test cup without reading the drug test results and repeat steps 1-3, instructing the donor to recollect their sample with a new test cup.
5: Read the results at 5 minutes. Results read after 10 minutes should be considered invalid.

How to Read the Drug Test Results:


  • Negative test results will have two lines - one line in the control region and one line in the test region.
  • Presumptive positive results will have only one line in the control region. If a test fails to show a line in the control region, this indicates and invalid test result.
  • Invalid drug results occur when no line appears in the control region. Should this occur, repeat the test with a new device. If results are still invalid, please stop using the test cups and contact TestCountry.

  •  
    Ordering More Than 75 Tests?
    Apply For Custom Pricing!
    CASE QTY:

    Why Customers Choose Us?

    Free Shipping on orders over $75

    Free Shipping on orders $75+

    $7 Shipping below $75

    Same day shipping for orders before 4pm EST

    Same-Day Shipping

    for Orders by 4pm EST

    Average Shelf Life of 12 to 18 months

    Average Shelf Life

    of Products is 12-18 Months

    5% of all profits go back into our community

    5% of All Profits

    Go Back Into Our Community

    DrugConfirm Urine Drug Screening

    Our DrugConfirm Advanced 5 Panel Flat Sided Instant Drug Test Cup is a fully-integrated test cup that detects 5 different drugs of abuse and also includes adulterant testing and a temperature strip to help prevent specimen tampering by the donor.

    This test cup detects the following drugs in a simple urine sample:

    • Amphetamines (AMP)
    • Cocaine (COC)
    • Marijuana (THC)
    • Methamphetamines (mAMP)
    • Opiates (OPI)

    Plus the following adulterants:

    • Oxidants (OX)
    • Specific Gravity (SG)
    • pH Levels
    The flat panel results window makes for ease of photocopying results for your drug testing program records. Once the testing is completed and the cup is sealed, the test is biohazardous safe so you can simply throw the cup and sample away when you are done.

    Our DrugConfirm Advanced test cup provides hospital quality results within 5 minutes with up to 99% results accuracy. Staffing agencies, human resource departments, law enforcement agencies and more all love this cup!

    If I suspect recent drug use, when should I collect a urine specimen for this test?

    The minimum detection time for most drugs is approximately 2 to 7 hours, so you may collect a urine sample after this time frame.

    What is a drug test cut-off level?

    The drug test cut-off level is the specified amount of a specific drug metabolite in a urine sample. Above this level, the test is considered positive. Below this level, a test is considered negative.

    5 Panel Drug Test Cup Instructions for Use:


    1: Remove test cup from the foil pouch and label the device with the donor's information.
    2: Remove the test cup lid and instruct the donor to urinate directly into the cup, making sure to provide a sample that's between the minimum line of 30ml and the maximum line of 110ml.
    3: Once the donor has collected their urine sample, ask them to securely place the lid back on the test device, then return the test to the collection official.
    4: Peel back the label to reveal the test panels and verify the adulteration strip against the color chart provided. If results indicate that adulteration has occurred, discard the test cup without reading the drug test results and repeat steps 1-3, instructing the donor to recollect their sample with a new test cup.
    5: Read the results at 5 minutes. Results read after 10 minutes should be considered invalid.

    How to Read the Drug Test Results:


  • Negative test results will have two lines - one line in the control region and one line in the test region.
  • Presumptive positive results will have only one line in the control region. If a test fails to show a line in the control region, this indicates and invalid test result.
  • Invalid drug results occur when no line appears in the control region. Should this occur, repeat the test with a new device. If results are still invalid, please stop using the test cups and contact TestCountry.

  •